TRP-C31M - Modbus TCP to ASCII/RTU Gateway |
|
|
|
|
|
|
The TRP-C31M MODBUS gateway allows the legacy MODBUS RTU/ASCII devices to operate on a MODBUS TCP network. It allows either MODBUS serial master or slave to communicate with MODBUS TCP’s slave or master.
When the TRP-C 31M functions as a MODBUS TCP master to RTU/ASCII slave, it allows multiple MODBUS TCP masters to communicate with a MODBUS serial network. The queries from different masters are pipelined and processed one by one.
When TRP-C 31M functions as MODBUS RTU/ASCII master to MODBUS TCP slave, it can connect up to 8 MODBUS TCP slaves.The user can specify a UID range for each MODBUS TCP slave.
The TRP-C 31M has an inactive timeout. This allows the user to specify a time period to disconnect TCP/IP connection if there is no activity in the network and prevent any further connection.
User-friendly management software provides an easy way of configuration of Ethernet. The TRP-C 31M operates a Loop back Mode, where all data is sent back immediately. This feature makes the connection testing easy.
The industry standard DIN rail and panel mount design ensures a fast and professional installation. |
|
|
|
 |
Features |
|
- DIN rail or Panel mount
-
Supports 10/100 Mbps Ethernet
-
Supports RS-232, RS-422, and RS-485 serial interface
-
Supports LAN and WAN communications
-
Management access password protected
-
High speed up to 230.4Kbps
-
Supports 8 MODBUS TCP master to MODBUS RTU/ASCII slave (up to 31)
-
Supports MODBUS RTU/ASCII master to MODBUS/TCP slave devices (up to 8)
-
Provides inactive timeout for connection auto-recovery when power fails
-
Automatically generates exception report when RTU/ASCII slave device does not response
-
Remote IP address filtering function to reject unwanted incoming connection source
|
 |
Specifications |
|
- Output: 64K bytes
-
Input: 8K bytes
-
Serial Connection: DTE – BD-9 male
-
LAN: 10/100 Mbps Auto-detecting
-
RS-232: TX, RX, RTS, CTS, DTR, DSR, DCD, GND
-
RS-422: TX+, TX-, RX+, RX-, RTS+, RTS-, CTS+, CTS-, GND
-
RS-485: Data +, Data –, GND
-
Data Rate: 110 bps to 230.4 k bps
-
Parity: none, even, odd, mark, space
-
Data Bits: 5, 6, 7 or 8
-
Stop Bits: 1, 1.5 or 2
-
Protocol: TCP, IP, ARP, DHCP, Telnet, HTTP, UDP, ICMP
-
Power Requirements: 9 ~15 VDC / 500 mA
-
Operating Temperature:0 to 60℃
-
Storage Temperature: -20 to 70℃
-
Humidity: 10~ 90% Non-Condensing
-
Dimensions: 151mm x 77mm x 26mm
-
Weight: 377g
|
|
|  |